WL3100/WL3100A Dry Pressure Transducer
WL3100/WL3100A Dry Pressure Transducer

WL3100/WL3100A Dry Pressure Transducer

Other models available

WL3100 is a dry/dry differential pressure transducer. The difference between the pressure on the high and low pressure ports is linearized and converted to a usable 4-20 mA current output and made available as a digital serial SDI-12 output. The SDI-12 output…  Read more

Range  0-5 m, 0-10 m, 0-15 m, 0-20 m, 0-40 m, 0-50 m water head
Accuracy +/-0.02 % FS (full temperature compensation)
Overpressure 2.67 x range
Longterm Stability Typically +/-0.05 % FS per annum
Power Supply Operating : 9.6 -16 V DC
Outputs 4-20 mA, SDI-12 (up to 60 m); RS232 (with optional SDI-12 to RS232 adapter SE231)
Connectors
  • Standard: pluggable screw termination block
  • Optional: MIL spec connectors
Enclosure Powder-coated aluminium
Ingress Protection IP65
Programmable LCD
  • Type: 2 x lines x 16 characters
  • Backlighting (powered by external battery)
  • Displays: range, water level, battery voltag
Pressure Transducer Connection

Pressure Transducer Connection

Operating Temperature
  • WL3100:  -20 °C to 70 °C (transducer only, excludes LCD Display)
  • WL3100A: -40 °C to 70 °C (transducer and OLED Display)
Operating Relative Humidity Range 0 - 95 % non-condensing
Dimensions and Mass L x H x D: 180 mm x 105 mm x 100 mm; 1.2 k

WL3100 is a dry/dry differential pressure transducer. The difference between the pressure on the high and low pressure ports is linearized and converted to a usable 4-20 mA current output and made available as a digital serial SDI-12 output. 

The SDI-12 output transmits up to a distance of 60 m (200 ft). The 4-20 mA and SDI-12 outputs can operate simultaneously allowing redundant connection to up to 2 data loggers or RTUs.

WL3100 and WL3100A are mounted in a vented rugged aluminium enclosure.

The WL3100 transducer is available as ‘stand alone’ for connection to HS23 dry bubble units (see fl ipside) or can be fi tted as a component of the HS40 Series II or HS40 Compact bubbler system.

Two models: WL3100 and WL3100A

The two units share the same base technology and have very similar specs. The WL3100A is an advanced model with a wider temperature range starting at -40 °C and additional location correction factor to better account for atmospheric pressure infl uence, especially in particularly elevated or deep sites.

  • High accuracy +/-0.02 % full scale
  • Compatible with many pressure measurement applications
  • Available in ranges from 5 m (16 ft) to 50 m (164 ft)
  • SDI-12 and 4-20mA output at the same time
  • Low power consumption
  • Factory calibrated by HyQuest Solutions with certificat
  • Surface Water
  • Ground Water
  • Waste Water
  • Reservoirs and Dams
  • Lakes